Dymenzions
The software that really makes the difference...
Dymenzions Calculations & Design helps you set up a Safety Loop based on:
- SRS (Safety Requirements Specification)
- Design and calculation of the safety loop
- Design Verification
- Verification of the installation
- In the Engineering & Design phase of the safety functions you can make a number of choices based on SRS data, submitted by Hazop/Lopa outcome. In the engineering phase you can interactively design SIFs (Safety Instrumented Functions). Dymenzions contains an extensive database with up-to-date information of process equipment, such as failure rates, SIL certificates and safety manuals. Dymenzions Calculations & Design automatically calculates and determines the SIF associated parameters such as test frequencies, MTTR and spurious trip rate. Dymenzions provides a verification of your SIF loops based on your SRS and calculates whether it meets the required SIL level. In this way you can obtain an on-line design verification.
Calculations
& Design
Introduction
Calculations & Design offers the possibility to manage all steps in the design of functional safety, as described in the IEC61511 standard, in one place.
Description
SRS
SRS is a specification of the safety function. Dymenzions guides you in an interactive way to collect all necessary information for making an SRS and supports you in making design choices. Dymenzions efficiently incorporates data from the HAZOP and LOPA, such as:
- Required risk reduction and SIL level and required response time
- Function and location of the sensors and end elements
- For the safety functions you make a number of choices, such as
- Recommended minimum SFF (“Safe Failure Fraction”) for all components in the full SIL life cycle
- Configuration and wishes regarding redundancy and tuning (1oo2, 1oo3, 2oo3 etc.)
- Required availability
A user specification for a safety system may also include:
- Maintenance Override functions
- Communication with other systems
- All desired brands and models of components, such as PLC, transmitters, barriers and valves.
- Hardware Requirements: ATEX Classification and Materials
- Description of alarm handling and required personnel action.
You can print a current SRS document at any time.
SIL / SIF Design
Dymenzions Calculations & Design makes it easy to design SIF loops. The system has a database of failure rates, SIL certificates and safety manuals for the most common components in process technology. You select the equipment and the system calculates parameters such as PFD average per component, PFD average for the entire loop, test frequencies, MTTR (Mean Time To Repair), Spurious Trip Rate, etc. Dymenzions also checks whether all requirements specified by you in the SRS are met and whether the desired SIL level is achieved with the chosen instrumentation.
Advantages
Calculations &
Design
- Full documentation and recording of the functional safety lifecycle
- Assisting in the preparation of an SRS
- Designing SIL and SIF loops based on average PFD and SIL calculation
- Use an up-to-date manufacturer database with failure rates, SIL certificates and safety manuals
- Perform the online design verification
- Safety Lifecycle Assessments
- Checking for completeness of data
- Check the conformity status according to current safety legislation and regulations
Conclusion
With Calculations & Design you can manage the complete design phase of the functional safety lifecycle and perform online verifications and calculations.
Optimize your functional safety designs with Dymenzions Calculations & Design
In the world of process safety, it is crucial to accurately manage and verify every aspect of functional safety. Dymenzions plays a key role in this with the Calculations & Design module, which is specifically designed to streamline the design process of safety functions. This module allows you to manage all steps in the design of functional safety, as described in the IEC 61511 standard, in one place.
What does Dymenzions offer?
Calculations & Design?
Calculations & Design helps you set up a Safety Loop by guiding you through the different phases of the functional safety lifecycle:
-
Safety Requirement Specification (SRS): Dymenzions supports you in drawing up an accurate SRS by efficiently collecting all the necessary information. The system integrates data from HAZOP and LOPA analyses, such as required risk reduction, SIL level, and response times.
-
Safety Loop Design and Calculation: You can interactively design Safety Instrumented Functions (SIFs) based on SRS data. Dymenzions contains an extensive database of up-to-date information on process equipment, such as failure rates, SIL certificates, and safety manuals. The system automatically calculates important parameters such as test frequencies, MTTR, and Spurious Trip Rate.
-
Design Verification: Dymenzions provides an online verification of your SIF loops against the SRS and checks whether the required SIL level is met. This ensures that your design meets all legal requirements and that you have full documentation and registration of the functional safety lifecycle.
The benefits of Dymenzions Calculations & Design
Using the Calculations & Design module from Dymenzions offers several advantages:
-
Full documentation: You can document and record the complete functional safety lifecycle, which is essential for compliance and audits.
-
Accurate calculations: With advanced calculations of SIL and SIF loops based on PFD (Probability of Failure on Demand) averages and SIL calculations, you can optimize your safety designs.
-
User-friendly interface: The interactive interface makes it easy to design and verify safety functions, while benefiting from an extensive database of up-to-date process equipment information.
-
Online design verification: Dymenzions offers the possibility to perform design verifications online, giving you immediate insight into the conformity of your design with current safety standards.
-
Compliance Check: The system helps you check the compliance status of your designs according to applicable safety laws and regulations.
In summary